HP-5ms · 19091S-433
Evaluate GsBP-5MS · 1525-3002 as a candidate with a 30 m × 0.25 mm × 0.25 μm specification.
View candidate
GS-TEK GsBP™ GC COLUMNS
Search GC columns by part number, stationary phase or application. Send your shortlist and method requirements to WeikeTory for selection support and a quotation.
Explore 16 common specificationsCandidate matches are not guarantees of identical performance. Method verification is required.

AGILENT ALTERNATIVE SELECTION
Evaluate GsBP-5MS · 1525-3002 as a candidate with a 30 m × 0.25 mm × 0.25 μm specification.
View candidateEvaluate GsBP-624 · 6232-3018 as a candidate with a 30 m × 0.32 mm × 1.8 μm specification.
View candidateCheck the full part number, stationary phase, length, internal diameter, film thickness, temperature limits and instrument conditions. MS and UI variants must not be assumed interchangeable. Confirm suitability using your actual samples and method.
PRODUCT CATALOG
Common specifications shown below; ask us about other dimensions, packed columns and custom requirements.
16 specifications
1525-3002
95% dimethyl / 5% diphenyl polysiloxane
30 m × 0.25 mm × 0.25 μmGC/MS screening, semivolatiles, environmental and food analysis
HP-5MS DB-5MS Rtx-5MS 19091S-433 EPA 8270
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
1125-3002
100% dimethyl polysiloxane
30 m × 0.25 mm × 0.25 μmNonpolar compounds, hydrocarbons and GC/MS
HP-1MS DB-1MS Ultra-1
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
0532-3002
95% dimethyl / 5% diphenyl polysiloxane
30 m × 0.32 mm × 0.25 μmRoutine analysis, quality control, solvents and hydrocarbons
HP-5 DB-5 Rtx-5 SE-54
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
0125-3010
100% dimethyl polysiloxane
30 m × 0.25 mm × 1.0 μmHydrocarbons, nonpolar analytes and petrochemical C6+
HP-1 DB-1 SPB-1
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
6232-3018
Approximately 6% cyanopropylphenyl phase
30 m × 0.32 mm × 1.8 μmEnvironmental VOCs and pharmaceutical residual solvents
HP-624 DB-624 Rtx-624 123-1334 EPA 8260 USP 467
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
6425-3014
VOC-specific stationary phase
30 m × 0.25 mm × 1.4 μmVOCs and volatile organic compound methods
DB-VRX DB-502.2 Rtx-VMS EPA 8260
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
2025-3002
Crosslinked polyethylene glycol (PEG)
30 m × 0.25 mm × 0.25 μmPolar compounds, solvents, flavors and FAME
HP-Innowax DB-Wax Stabilwax ZB-WAX
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
2125-3002
Acid-modified PEG
30 m × 0.25 mm × 0.25 μmOrganic acids and volatile fatty acids
HP-FFAP DB-FFAP Stabilwax-DA
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
6125-3002
14% cyanopropylphenyl / 86% dimethyl polysiloxane
30 m × 0.25 mm × 0.25 μmPesticides, pharmaceuticals and mixed-polarity analytes
HP-1701 DB-1701 Rtx-1701
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
5025-3002
50% diphenyl / 50% dimethyl siloxane
30 m × 0.25 mm × 0.25 μmMedium-polarity compounds, pesticides and confirmation analysis
DB-17MS HP-50+
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
8253-3015
Sodium sulfate-modified alumina
30 m × 0.53 mm × 15 μmC1–C5 light hydrocarbons and petrochemical gases
HP-PLOT Al2O3 Rtx-Alumina ASTM
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
8453-3050
5A molecular sieve
30 m × 0.53 mm × 50 μmPermanent gases: oxygen, nitrogen, CO, methane and hydrogen
HP-PLOT Molesieve CP-Molesieve ASTM
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
8653-3030
Crosslinked polydivinylbenzene
30 m × 0.53 mm × 30 μmCO₂, water, sulfur compounds and volatile components
HP-PLOT Q GS-Q Rt-QPLOT
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
8532-3005
Modified porous silica layer
30 m × 0.32 mm × 5 μmTrace sulfur compounds, H₂S, COS and mercaptans
GS-GasPro CP-SilicaPLOT
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
3525-3002
65% dimethyl / 35% diphenyl polysiloxane
30 m × 0.25 mm × 0.25 μmPesticides, confirmation analysis and medium-polarity compounds
DB-35MS Rtx-35
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
1625-3002
Proprietary low-bleed phase
30 m × 0.25 mm × 0.25 μmComplex pesticide and environmental contaminant analysis
DB-XLB Rtx-XLB MDN-12
Screening reference only. Confirm exact specifications, phase selectivity and method suitability before replacement.
No exact match found. Add your current part number and method to the inquiry below.
ABOUT GS-TEK
GS-TEK was founded in Delaware, USA, in 2009 by Dr. Zhenghua “Zack” Ji. Before founding the company, he worked in chromatography column and analytical instrument development at Hewlett-Packard / Agilent. A 2011 interview describes his involvement in the development of capillary GC columns including HP-5ms.
This background helps explain GS-TEK’s technical focus; it does not establish affiliation with Agilent or guarantee that two columns perform identically. Product specifications and method validation remain essential.
GS-TEK company information · 2011 founder interview (Chinese)
REQUEST A QUOTATION
No products selected. You can still send your current part number and requirements.
Your inquiry is prepared in this browser. Form entries and selected products are not submitted to our server by this page. They are sent only when you send the email through your email application or share the copied text. Refreshing this page clears the inquiry. We use information you send to respond to your request.
Contact: sales@weiketory.com · +86 186-1262-2518